  Datasheet File OCR Text:
 Plug-in Connectors for DISK Unit
FX2M3 Series
sFeatures
1. Plug-in Connector Equipped with Power contact
The total number of contacts contains 128 contacts, of which 120 contacts belong to the half pitch signal contacts, and the remained 8 contacts are used for the power contact. The power contact corresponds to the high current (7.5A).
2. Three-stage Sequential Structure
Considering the plug and play, 3 stages sequential structure is employed.
3. Flux Tight
The signal contact area of the straight through hole type has completely prevented flux swell due to solder dipping.
4. Bus Line Connection
The socket side connector allow to connect the bus line.
5. Floating Mechanism
The socket type employs the floating (=1mm) mechanism for the panel installation.
Floating Mechanism
Bus Line Connection (Power Supply Side)
FX2M3-128S8-RC Use Example
Bus Line Connection (For Signal)
Since the signal contact can be engaged or disengaged, connection The power contact allows to connect the bus line. c1 -------------- c2 c3 -------------- c4 c5 -------------- c6 c7 -------------- c8 Short inside the connector at every 2 contacts. can be performed in combination with the cable type and the terminator as illustrated on the left.
A177
sApplications
Office computers and other information processsing machines
sProduct Specifications
Rating Current rating Signal contact: 0.5A Operating Temperature Range: -55c to +85c Note 1. Storage Temperature Range: -10c to +60c Note 2. Voltage rating 125V AC Power contact: 7.5A Operating Humidity Range : 40% to 80% Storage Humidity Range: 40% to 70%
Item 1. Insulation Resistance 2. Withstanding voltage 3. Contact Resistance 4. Vibration 5. Humidity (Steady state) 6. Temperature Cycle 7. Durability (Mating/un-mating) 8. Resistance to Soldering heat
Specifications Signal contact 100M ohms min. Power contact 1000M ohms min. 250V DC
Condition
No flashover or insulation breakdown.
Signal contact 45m ohms max. Power contact 30m ohms max.
Signal contact 300V AC for 1 minute Power contact 1000V AC for 1 minute 100mA
No electrical discontinuity of 1s or more
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions.
Signal Contact Resistance: 55m ohms max.Insulation Resistance: 100M ohms min. 96 hours at temperature of 40c and humidity of 90% to 95% Contact Contact Resistance: 30m ohms max. Insulation resistance: 1000M ohms min. Signal Contact Resistance: 55m ohms max. Insulation resistance: 100m ohms min. Contact Contact resistance: 30m ohms max. Insulation resistance: 1000m ohms min. Signal contact Contact resistance: 55m ohms max. Power contact Contact resistance: 30m ohms max. (-55c: 30 minutes 15 to 35c: 2 to 3 minutes (-85c: 30 minutes 15 to 35c: 2 to 3minutes) 5 cycles 30 cycles
No deformation of components affecting performance.
Reflow: At the recommended temperature profile Manual soldering: 300c for 10 seconds
Note 1: Includes temperature rise caused by current flow. Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and Humidity range covers non conducting condition of installed connectors in storage, shipment or during transportation.
sMaterial
Parts Insulator Header Termination connector Header Signal contact Receptacle, Termination connector Cable connector Header Power contact Receptacle Socket Material PBT/Polyamide PPS Brass Phosphor bronze Beryllium copper Brass Phosphor bronze Copper alloy Finish Black Light brown Selective gold plated Slective gold plated Selective gold plated Tin plated Tin plated Tin plated ________ ________ Remarks UL94V-0 UL94V-0
A178
sOrdering Information
FX 2M3 - 128 S 8 - DSA L
q w e r t y
q Series name w 128 e Connector types
: FX2M3 : (Total Contact number) : S : Receptacle or Socket P : Header
t Contact type DSA DS RC : Straight through hole : Right angle through hole : Socket (Note 1)
r 8: Power contact number
y L: Board prefixed pin attached
q60 Contacts Engage/Disengage Connector
FX 2BA - 60 S - 1.27 R/L
q w e r t y
q Series name w Series No.
: FX : 2BA..Cable connector 2M3..Termination connector
r Connector type
: S. Socket (Cable connector) Receptacle (Termination connector)
t Contact pitch..1.27mm y R/L : ID connection type SH : Pinching SMT type
e Number of contacts : 60
Part Number FX2M3-128S8-RC FX2M3-128P8-DSL FX2M3-128S8-DSAL FX2M3-128P8-DSAL FX2BA-60S-1.27R/L FX2M3-60S-1.27SH
CL No. 572-1007-0 572-1008-2 572-1009-5 572-1010-4 572-1026-4 572-1020-8
Number of Contacts Signal ___ (NOTE1) 602 602 602 60 (NOTE2) 60 (NOTE2) Power 8 8 8 8 ______ ______ Socket side
Remarks
Header side, Right angle through hole Receptacle side, Straight through hole Header side, Straight through hole Cable connector Termination connector
NOTE 1 : The signal connector is uninstalled. (Use FX2BA-60S-1.27R/L or FX2M3-60S-1.27SH.) NOTE 2 : Installation to FX2M3-128S8-RC possible.
A179
sSocket
FX2M3-128S8-RC CL572-1007-0
NOTE: The signal connector is uninstalled in this product. Use FX2BA-60S-1.27R/L or FX2M3-60S-1.27SH.
BPower contact Detailed View
Please use the marketed tub Contact (product compliant to JIS standard: JIS2809) to connect the cable in the power contact area. (However, use phosphor bronze as material.)
BCombination View
(FX2BA-60S-1.27R/L or FX2M3-60S-1.27SH is installed in this product.)
A180
sCable Connector
FX2BA-60S-1.27R/L CL572-1026-4
NOTE: This product can be installed in FX2M3-128S8-RC. Applicable cable: 1.27 pitch flat cable AWG28 (7/0.127) insulation covering diameter 0.9mm
BCable Assembly View
sTermination Connector
FX2M3-60S-1.27SH CL572-1020-8
NOTE: The locking type is prepared for the termination connector. Contact the HRS PCC Technical Department for details.
A181
sHeader
qRight Angle Type
FX2M3-128P8-DSL CL572-1008-2
qStraight Type
FX2M3-128P8-DSAL CL572-1010-4
A182
sReceptacle
qStraight Type
FX2M3-128S8-DSAL CL572-1009-5
A183
BPCB mounting pattern
qFX2M3-128P8-DSL
qFX2M3-128P8-DSAL
qFX2M3-128S8-DSAL
A184
BPanel Cutouts (Mounted on Rear Side)
qFX2M3-128S8-RC
qFX2M3-128P8-DSL
BFX2M3-60S-1.27SH PCB mounting pattern
A185
BApplication Pattern
Floating range 1.0mm
Floating range 1.0mm
A186
BFX2M3-128S8-RC Operating Instructions
A187
FX2M3-128S8-RC Use Example
Power Side
The power contact allows to connect the bus line. c1 -------------- c2 c3 -------------- c4 c5 -------------- c6 c7 -------------- c8 Short inside the connector at every 2 contacts. Since the signal contact can be engaged or disengaged, the contact can be used in combination with the cable type and the terminator as illustrated on the left.
Signal Side
A188


▲Up To Search▲   

 
Price & Availability of FX2BA-60S-127RL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X